Online catalogue
Comparison list: 0 Article
Inquiry: 0 Article
Enclosure (glasfibre reinforced polyester), pillar design with plugged door
Dimensions (HxWxD): 1415x316x228mm
Degree of protection: IP44
Applications: f.ex. distribution cabinet, service entrance, customized configuration
(see details)
1 - 6 (12)Number:
Product Features
h_h9060002_20150715_001_b.tif
DescriptionGehäuse aus glasfaserverstärktem Polyester in Säulenbauform mit Stecktür
bestückt mit Sammelschienensytem, Einspeisung: direkt (ungesichert) und
Abgang: 2 NH00 Sicherungsleisten
Special features: Busbar system
direct feeding (fuseless, terminals)
Outgoing units: 2 NH00 strip-fuseways
Interior: Busbarsystem with LV HRC strip-fuseways
DescriptionGehäuse aus glasfaserverstärktem Polyester in Säulenbauform mit Stecktür
bestückt mit Sammelschienensytem, Einspeisung: direkt (ungesichert) und
Abgang: 2 NH00 Sicherungsleisten
Special features Busbar system
direct feeding (fuseless, terminals)
Outgoing units: 2 NH00 strip-fuseways
Interior Busbarsystem with LV HRC strip-fuseways
has_1.jpg
Description
Special features: Busbar system
direct feeding (fuseless, terminals)
Outgoing units: 1 NH2 strip-fuseway
Interior: Busbarsystem with LV HRC strip-fuseways
Special features Busbar system
direct feeding (fuseless, terminals)
Outgoing units: 1 NH2 strip-fuseway
Interior Busbarsystem with LV HRC strip-fuseways
h9_hausanschlusssaeule_has_es_1xl00(2)_esp_pg42_h9060018_nahaufnahme_.jpg
Description
Special features: Sammelschienensytem 30x5
Bestückt mit:
ESP direkt (ungesichert) mit 2x Flat directconnection Klemme (35-185mm²)

1x NH00 NH-Sicherungsleiste L00-3/185/KU00/HA
1x HRF Reservefeldabdeckung NH00
Interior: Busbarsystem with LV HRC strip-fuseways
Special features Sammelschienensytem 30x5
Bestückt mit:
ESP direkt (ungesichert) mit 2x Flat directconnection Klemme (35-185mm²)

1x NH00 NH-Sicherungsleiste L00-3/185/KU00/HA
1x HRF Reservefeldabdeckung NH00
Interior Busbarsystem with LV HRC strip-fuseways
h_gehaeusetechnik_fuer_energieverteilung_2009_20090824_010-1.tif
Description
Special features: Busbarsystem
Direct feeding in centre (fuseless, terminals)
Outgoing units: 4 NH00 strip-fuseways (left/right, two each side)
Interior: Busbarsystem with LV HRC strip-fuseways
Special features Busbarsystem
Direct feeding in centre (fuseless, terminals)
Outgoing units: 4 NH00 strip-fuseways (left/right, two each side)
Interior Busbarsystem with LV HRC strip-fuseways
h_gehaeusetechnik_fuer_energieverteilung_2009_20090824_010-1.tif
DescriptionBusbar system
Directing (fuseless, terminals) in centre
Outgoing units (left/right): 1x NH2 strip-type fuse-switch-disconnector each
Special features: Busbbar system
Feeding: centre, direct (fuseless, terminals)
Outgoing units: left/right 1 NH2 strip-type fuse-switch-disconnector
Interior: Busbarsystem with LV HRC fuse-switch-disconnectors
DescriptionBusbar system
Directing (fuseless, terminals) in centre
Outgoing units (left/right): 1x NH2 strip-type fuse-switch-disconnector each
Special features Busbbar system
Feeding: centre, direct (fuseless, terminals)
Outgoing units: left/right 1 NH2 strip-type fuse-switch-disconnector
Interior Busbarsystem with LV HRC fuse-switch-disconnectors
h_gehaeusetechnik_fuer_energieverteilung_2009_20090824_010-1.tif
Description
Special features:

Busbar system
Direct feeding (fuseless, terminals)
Outgoing units: 1 NH2 strip-type fuse-switch-disconnectors
Single locking

Interior: Busbarsystem with LV HRC fuse-switch-disconnectors
Special features

Busbar system
Direct feeding (fuseless, terminals)
Outgoing units: 1 NH2 strip-type fuse-switch-disconnectors
Single locking

Interior Busbarsystem with LV HRC fuse-switch-disconnectors
1 - 6 (12)