1 - 6 (9)Number:
Product Features
t_ltl4a_1x_ssm.tif
Descriptionaccording to EN60947-3, size NH4a - 1250A, 3pole/3pole switchable
for mounting on busbar system
with universal terminal 1xM16
cable terminal at top
Rated operating voltage Ue: 690 V
Rated operating current Ie: 1,250 A
Cable terminal: Flat terminal M16
Poles: 1
Descriptionaccording to EN60947-3, size NH4a - 1250A, 3pole/3pole switchable
for mounting on busbar system
with universal terminal 1xM16
cable terminal at top
Rated operating voltage Ue 690 V
Rated operating current Ie 1,250 A
Cable terminal Flat terminal M16
Poles 1
t_ltl4a_1x.tif
DescriptionNH fuse switch disconnector
according to EN60947-3, size NH4a - 1250A, 1 pole
for mounting on mounting plate
with screw connection M16
Cable connection top and bottom
Rated operating voltage Ue: 690 V
Rated operating current Ie: 1,250 A
Cable terminal: Flat terminal M16
Poles: 1
DescriptionNH fuse switch disconnector
according to EN60947-3, size NH4a - 1250A, 1 pole
for mounting on mounting plate
with screw connection M16
Cable connection top and bottom
Rated operating voltage Ue 690 V
Rated operating current Ie 1,250 A
Cable terminal Flat terminal M16
Poles 1
t_ltl4a_1x.tif
Descriptionaccording to EN60947-3, size NH4a - 1600A, 1pole/1pole switchable
for baseplate mounting
with universal terminal 2xM12
cable terminal at top and bottom side
Rated operating voltage Ue: 690 V
Rated operating current Ie: 1,600 A
Cable terminal: 2xM12 for direct connection of busbar (not suitable for cable connection)
Poles: 1
Descriptionaccording to EN60947-3, size NH4a - 1600A, 1pole/1pole switchable
for baseplate mounting
with universal terminal 2xM12
cable terminal at top and bottom side
Rated operating voltage Ue 690 V
Rated operating current Ie 1,600 A
Cable terminal 2xM12 for direct connection of busbar (not suitable for cable connection)
Poles 1
t_ltl4a_1x_ssm.tif
Descriptionaccording to EN60947-3, size NH4a - 1250A, 3pole/3pole switchable
for mounting on busbar system
with universal terminal 1xM16
cable terminal at bottom
Rated operating voltage Ue: 690 V
Rated operating current Ie: 1,250 A
Cable terminal: Flat terminal M16
Poles: 1
Descriptionaccording to EN60947-3, size NH4a - 1250A, 3pole/3pole switchable
for mounting on busbar system
with universal terminal 1xM16
cable terminal at bottom
Rated operating voltage Ue 690 V
Rated operating current Ie 1,250 A
Cable terminal Flat terminal M16
Poles 1
t_ltl4a.tif
Descriptionaccording to EN60947-3, size NH4a - 1250A, 3pole/1pole switchable
for baseplate mounting
with universal terminal 1xM16
cable terminal at top and bottom side
Rated operating voltage Ue: 690 V
Rated operating current Ie: 1,250 A
Cable terminal: Flat terminal M16
Poles: 3
Descriptionaccording to EN60947-3, size NH4a - 1250A, 3pole/1pole switchable
for baseplate mounting
with universal terminal 1xM16
cable terminal at top and bottom side
Rated operating voltage Ue 690 V
Rated operating current Ie 1,250 A
Cable terminal Flat terminal M16
Poles 3
t_ltl4a.tif
Descriptionaccording to EN60947-3, size NH4a - 1600A, 3pole/1pole switchable
for baseplate mounting
with universal terminal 2xM12
cable terminal at top and bottom side
Rated operating voltage Ue: 690 V
Rated operating current Ie: 1,600 A
Cable terminal: 2xM12 for direct connection of busbar (not suitable for cable connection)
Poles: 3
Descriptionaccording to EN60947-3, size NH4a - 1600A, 3pole/1pole switchable
for baseplate mounting
with universal terminal 2xM12
cable terminal at top and bottom side
Rated operating voltage Ue 690 V
Rated operating current Ie 1,600 A
Cable terminal 2xM12 for direct connection of busbar (not suitable for cable connection)
Poles 3