NH fuse-links utilization category gTr for transformer protection according to DIN VDE 0636-2011 with a rated voltage of AC400V.
1 - 6 (9)Number:
Product Features
N_M3GTR910_400V_100kA_N3307500.png
Description
Utilization category: gTr
Rated voltage AC: 400 V
Size: NH3
Rated current: 722 A
Transformer rating: 500 kVA
Indicator / Signalling: Centre indicator
Contact type: Blade contact
Gripping lugs: live
Utilization category gTr
Rated voltage AC 400 V
Size NH3
Rated current 722 A
Transformer rating 500 kVA
Indicator / Signalling Centre indicator
Contact type Blade contact
Gripping lugs live
N_M3GTR910_400V_100kA_N3307500.png
Description
Utilization category: gTr
Rated voltage AC: 400 V
Size: NH3
Rated current: 722 A
Transformer rating: 500 kVA
Indicator / Signalling: Top indicator
Contact type: Blade contact
Gripping lugs: live
Utilization category gTr
Rated voltage AC 400 V
Size NH3
Rated current 722 A
Transformer rating 500 kVA
Indicator / Signalling Top indicator
Contact type Blade contact
Gripping lugs live
N_M3GTR910MI_400V_100kA_N3307504.png
Description
Utilization category: gTr
Rated voltage AC: 400 V
Size: NH3
Rated current: 909 A
Transformer rating: 630 kVA
Indicator / Signalling: Centre indicator
Contact type: Blade contact
Gripping lugs: live
Utilization category gTr
Rated voltage AC 400 V
Size NH3
Rated current 909 A
Transformer rating 630 kVA
Indicator / Signalling Centre indicator
Contact type Blade contact
Gripping lugs live
N_M3GTR910_400V_100kA_N3307500.png
Description
Utilization category: gTr
Rated voltage AC: 400 V
Size: NH3
Rated current: 909 A
Transformer rating: 630 kVA
Indicator / Signalling: Top indicator
Contact type: Blade contact
Gripping lugs: live
Utilization category gTr
Rated voltage AC 400 V
Size NH3
Rated current 909 A
Transformer rating 630 kVA
Indicator / Signalling Top indicator
Contact type Blade contact
Gripping lugs live
N_M3GTR910_400V_100kA_N3307500.png
Description
Utilization category: gTr
Rated voltage AC: 400 V
Size: NH4a
Rated current: 577 A
Transformer rating: 400 kVA
Indicator / Signalling: Top indicator
Contact type: Blade contact
Gripping lugs: live
Utilization category gTr
Rated voltage AC 400 V
Size NH4a
Rated current 577 A
Transformer rating 400 kVA
Indicator / Signalling Top indicator
Contact type Blade contact
Gripping lugs live
N_M3GTR910_400V_100kA_N3307500.png
Description
Utilization category: gTr
Rated voltage AC: 400 V
Size: NH4a
Rated current: 722 A
Transformer rating: 500 kVA
Indicator / Signalling: Top indicator
Contact type: Blade contact
Gripping lugs: live
Utilization category gTr
Rated voltage AC 400 V
Size NH4a
Rated current 722 A
Transformer rating 500 kVA
Indicator / Signalling Top indicator
Contact type Blade contact
Gripping lugs live
1 - 6 (9)