Descriptionaccording to IEC60269-2, size NH1 - 250A
DELTA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with screw terminal M10
with terminal cover
Rated operating voltage Ue:
|
690 V
|
Rated operating current Ie:
|
250 A
|
Cable terminal:
|
Flat terminal M10
|
Poles:
|
3
|
Fuse monitoring:
|
None
|
|
Descriptionaccording to IEC60269-2, size NH1 - 250A
DELTA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with screw terminal M10
with terminal cover
|
Rated operating voltage Ue
|
690 V
|
Rated operating current Ie
|
250 A
|
Cable terminal
|
Flat terminal M10
|
Poles
|
3
|
Fuse monitoring
|
None
|
|
|
|
Descriptionaccording to IEC60269-2, size NH1 - 250A
GAMMA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with screw terminal M10
with terminal cover
Rated operating voltage Ue:
|
690 V
|
Rated operating current Ie:
|
250 A
|
Cable terminal:
|
Flat terminal M10
|
Poles:
|
3
|
|
Descriptionaccording to IEC60269-2, size NH1 - 250A
GAMMA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with screw terminal M10
with terminal cover
|
Rated operating voltage Ue
|
690 V
|
Rated operating current Ie
|
250 A
|
Cable terminal
|
Flat terminal M10
|
Poles
|
3
|
|
|
|
Descriptionaccording to IEC60269-2, size NH1 - 250A
DELTA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with v-terminal and steel-frame clamp type KM2G-F, max. clamping range: 25 - 240mm²
with covers on each clamp
Rated operating voltage Ue:
|
690 V
|
Rated operating current Ie:
|
250 A
|
Cable terminal:
|
V box terminal KM2G-F 25-240mm²
|
Poles:
|
3
|
Fuse monitoring:
|
None
|
|
Descriptionaccording to IEC60269-2, size NH1 - 250A
DELTA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with v-terminal and steel-frame clamp type KM2G-F, max. clamping range: 25 - 240mm²
with covers on each clamp
|
Rated operating voltage Ue
|
690 V
|
Rated operating current Ie
|
250 A
|
Cable terminal
|
V box terminal KM2G-F 25-240mm²
|
Poles
|
3
|
Fuse monitoring
|
None
|
|
|
|
Description
Rated operating voltage Ue:
|
690 V
|
Rated operating current Ie:
|
250 A
|
Cable terminal:
|
V box terminal KM2G-F 25-240mm²
|
Poles:
|
3
|
Fuse monitoring:
|
None
|
|
|
Rated operating voltage Ue
|
690 V
|
Rated operating current Ie
|
250 A
|
Cable terminal
|
V box terminal KM2G-F 25-240mm²
|
Poles
|
3
|
Fuse monitoring
|
None
|
|
|
|
Descriptionaccording to IEC60269-2, size NH1 - 250A
GAMMA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with v-terminal and steel-frame clamp type KM2G-F, max. clamping range: 25 - 240mm²
with covers on each clamp
Rated operating voltage Ue:
|
690 V
|
Rated operating current Ie:
|
250 A
|
Cable terminal:
|
V box terminal KM2G-F 25-240mm²
|
Poles:
|
3
|
|
Descriptionaccording to IEC60269-2, size NH1 - 250A
GAMMA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with v-terminal and steel-frame clamp type KM2G-F, max. clamping range: 25 - 240mm²
with covers on each clamp
|
Rated operating voltage Ue
|
690 V
|
Rated operating current Ie
|
250 A
|
Cable terminal
|
V box terminal KM2G-F 25-240mm²
|
Poles
|
3
|
|
|
|
Description
Rated operating voltage Ue:
|
690 V
|
Rated operating current Ie:
|
250 A
|
Cable terminal:
|
V box terminal KM2G 25-300mm²
|
Poles:
|
3
|
|
|
Rated operating voltage Ue
|
690 V
|
Rated operating current Ie
|
250 A
|
Cable terminal
|
V box terminal KM2G 25-300mm²
|
Poles
|
3
|
|
|
|
Descriptionaccording to IEC60269-2, size NH1 - 250A
DELTA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with v-terminal and steel-frame clamp type KM2G, max. clamping range: 25 - 300mm²
with covers on each clamp
Rated operating voltage Ue:
|
690 V
|
Rated operating current Ie:
|
250 A
|
Cable terminal:
|
V box terminal KM2G 25-300mm²
|
Poles:
|
3
|
Fuse monitoring:
|
None
|
|
Descriptionaccording to IEC60269-2, size NH1 - 250A
DELTA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with v-terminal and steel-frame clamp type KM2G, max. clamping range: 25 - 300mm²
with covers on each clamp
|
Rated operating voltage Ue
|
690 V
|
Rated operating current Ie
|
250 A
|
Cable terminal
|
V box terminal KM2G 25-300mm²
|
Poles
|
3
|
Fuse monitoring
|
None
|
|
|
|
Descriptionaccording to IEC60269-2, size NH1 - 250A
DELTA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with stud bolt terminal M12x35
with terminal cover
Rated operating voltage Ue:
|
690 V
|
Rated operating current Ie:
|
250 A
|
Cable terminal:
|
Stud bolt terminal M12 x 35mm
|
Poles:
|
3
|
Fuse monitoring:
|
None
|
|
Descriptionaccording to IEC60269-2, size NH1 - 250A
DELTA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with stud bolt terminal M12x35
with terminal cover
|
Rated operating voltage Ue
|
690 V
|
Rated operating current Ie
|
250 A
|
Cable terminal
|
Stud bolt terminal M12 x 35mm
|
Poles
|
3
|
Fuse monitoring
|
None
|
|
|
|
Description
Rated operating voltage Ue:
|
690 V
|
Rated operating current Ie:
|
250 A
|
Cable terminal:
|
Stud bolt terminal M12 x 60mm
|
Poles:
|
3
|
|
|
Rated operating voltage Ue
|
690 V
|
Rated operating current Ie
|
250 A
|
Cable terminal
|
Stud bolt terminal M12 x 60mm
|
Poles
|
3
|
|
|
|
Descriptionaccording to IEC60269-2, size NH1 - 250A
OMEGA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with screw terminal M10
with terminal cover
Rated operating voltage Ue:
|
690 V
|
Rated operating current Ie:
|
250 A
|
Cable terminal:
|
Flat terminal M10
|
Poles:
|
3
|
Fuse monitoring:
|
None
|
|
Descriptionaccording to IEC60269-2, size NH1 - 250A
OMEGA-contact system
for mounting on 3pole busbar system with 185mm centre-to-centre distance
with screw terminal M10
with terminal cover
|
Rated operating voltage Ue
|
690 V
|
Rated operating current Ie
|
250 A
|
Cable terminal
|
Flat terminal M10
|
Poles
|
3
|
Fuse monitoring
|
None
|
|
|