Descriptionaccording to EN60947-3, size NH3 - 630A, 3pole for mounting on 3pole busbar system with 60mm centre-to-centre distance with screw terminal M10 x 25 cable terminal at top or bottom side, at customers option new design (black switching handle)
Type:
|
KETO-3-3/60/AOU/F
|
Size:
|
NH3
|
Rated operating voltage Ue:
|
690 V
|
Rated operating current Ie:
|
630 A
|
Cable terminal:
|
Flat terminal M10
|
Direction of cable terminal:
|
variable
|
busbar thickness:
|
5; 10 mm
|
Poles:
|
3
|
Fuse monitoring:
|
None
|
Width:
|
250 mm
|
|
Descriptionaccording to EN60947-3, size NH3 - 630A, 3pole for mounting on 3pole busbar system with 60mm centre-to-centre distance with screw terminal M10 x 25 cable terminal at top or bottom side, at customers option new design (black switching handle)
|
Type
|
KETO-3-3/60/AOU/F
|
Size
|
NH3
|
Rated operating voltage Ue
|
690 V
|
Rated operating current Ie
|
630 A
|
Cable terminal
|
Flat terminal M10
|
Direction of cable terminal
|
variable
|
busbar thickness
|
5; 10 mm
|
Poles
|
3
|
Fuse monitoring
|
None
|
Width
|
250 mm
|
|
|
|
Descriptionaccording to EN60947-3, size NH3 - 630A, 3pole
for mounting on 3pole busbar system with 60mm centre-to-centre distance
with screw terminal M10 x 25
cable terminal at top or bottom side, at customers option
with optical indicator in case of blown fuse-link (LED)
Type:
|
KETO-3-3/60/AOU/F/ESL
|
Size:
|
NH3
|
Rated operating voltage Ue:
|
500 V
|
Rated operating current Ie:
|
630 A
|
Cable terminal:
|
Flat terminal M10
|
Direction of cable terminal:
|
variable
|
busbar thickness:
|
5; 10 mm
|
Poles:
|
3
|
Fuse monitoring:
|
Local indicator (LED)
|
|
Descriptionaccording to EN60947-3, size NH3 - 630A, 3pole
for mounting on 3pole busbar system with 60mm centre-to-centre distance
with screw terminal M10 x 25
cable terminal at top or bottom side, at customers option
with optical indicator in case of blown fuse-link (LED)
|
Type
|
KETO-3-3/60/AOU/F/ESL
|
Size
|
NH3
|
Rated operating voltage Ue
|
500 V
|
Rated operating current Ie
|
630 A
|
Cable terminal
|
Flat terminal M10
|
Direction of cable terminal
|
variable
|
busbar thickness
|
5; 10 mm
|
Poles
|
3
|
Fuse monitoring
|
Local indicator (LED)
|
|
|
|
Descriptionaccording to EN60947-3, size NH3 - 630A, 3pole
for mounting on 3pole busbar system with 60mm centre-to-centre distance
with box clamp R300, max. clamping range: 95-300mm² Al/Cu
cable terminal at top or bottom side, at customers option
Type:
|
KETO-3-3/60/AOU/R300
|
Size:
|
NH3
|
Rated operating voltage Ue:
|
690 V
|
Rated operating current Ie:
|
630 A
|
Cable terminal:
|
Frame clamp R300 95-300mm²
|
Direction of cable terminal:
|
variable
|
busbar thickness:
|
5; 10 mm
|
Poles:
|
3
|
Fuse monitoring:
|
None
|
|
Descriptionaccording to EN60947-3, size NH3 - 630A, 3pole
for mounting on 3pole busbar system with 60mm centre-to-centre distance
with box clamp R300, max. clamping range: 95-300mm² Al/Cu
cable terminal at top or bottom side, at customers option
|
Type
|
KETO-3-3/60/AOU/R300
|
Size
|
NH3
|
Rated operating voltage Ue
|
690 V
|
Rated operating current Ie
|
630 A
|
Cable terminal
|
Frame clamp R300 95-300mm²
|
Direction of cable terminal
|
variable
|
busbar thickness
|
5; 10 mm
|
Poles
|
3
|
Fuse monitoring
|
None
|
|
|
|
Descriptionaccording to EN60947-3, size NH3 - 630A, 3pole
for mounting on 3pole busbar system with 60mm centre-to-centre distance
with box clamp R300, max. clamping range: 95-300mm² Al/Cu
cable terminal at top or bottom side, at customers option
with optical indicator in case of blown fuse-link (LED)
Type:
|
KETO-3-3/60/AOU/R300/ESL
|
Size:
|
NH3
|
Rated operating voltage Ue:
|
500 V
|
Rated operating current Ie:
|
630 A
|
Cable terminal:
|
Frame clamp R300 95-300mm²
|
Direction of cable terminal:
|
variable
|
busbar thickness:
|
5; 10 mm
|
Poles:
|
3
|
Fuse monitoring:
|
Local indicator (LED)
|
Width:
|
250 mm
|
|
Descriptionaccording to EN60947-3, size NH3 - 630A, 3pole
for mounting on 3pole busbar system with 60mm centre-to-centre distance
with box clamp R300, max. clamping range: 95-300mm² Al/Cu
cable terminal at top or bottom side, at customers option
with optical indicator in case of blown fuse-link (LED)
|
Type
|
KETO-3-3/60/AOU/R300/ESL
|
Size
|
NH3
|
Rated operating voltage Ue
|
500 V
|
Rated operating current Ie
|
630 A
|
Cable terminal
|
Frame clamp R300 95-300mm²
|
Direction of cable terminal
|
variable
|
busbar thickness
|
5; 10 mm
|
Poles
|
3
|
Fuse monitoring
|
Local indicator (LED)
|
Width
|
250 mm
|
|
|
|
Descriptionaccording to EN60947-3, size NH3 - 630A, 3pole
for mounting on 3pole busbar system with 60mm centre-to-centre distance
with screw terminal M10 x 25
cable terminal at top or bottom side, at customers option
with electronic fuse-monitoring unit ES10
Type:
|
KETO-3-3/60/AOU/F/ES10
|
Size:
|
NH3
|
Rated operating voltage Ue:
|
500 V
|
Rated operating current Ie:
|
630 A
|
Cable terminal:
|
Flat terminal M10
|
Direction of cable terminal:
|
variable
|
busbar thickness:
|
5; 10 mm
|
Poles:
|
3
|
Fuse monitoring:
|
Electronic Fuse Monitoring Unit ES10 Rated operational voltage: AC400-500V (+/-10%) Power supply: Self-powered Input power: 1,5VA Overvoltage category:
- 230/400V: III (4kV)
- 500V: II (4kV)
Input resistance: >1k Ohm/V Temperature range: -5 up to + 55
Relay output: 1NC/1NO Switching power:
- AC250V: 1A
- DC220V: 0,3A
- DC30V: 2A
Operation indicator: 1 LED green Alarm indicator: 3 LED (F1, F2, F3) red Functional test: Test key for relay + LEDs EMV: IEC 61000-4-5/IEC 61000-4-4
|
|
Descriptionaccording to EN60947-3, size NH3 - 630A, 3pole
for mounting on 3pole busbar system with 60mm centre-to-centre distance
with screw terminal M10 x 25
cable terminal at top or bottom side, at customers option
with electronic fuse-monitoring unit ES10
|
Type
|
KETO-3-3/60/AOU/F/ES10
|
Size
|
NH3
|
Rated operating voltage Ue
|
500 V
|
Rated operating current Ie
|
630 A
|
Cable terminal
|
Flat terminal M10
|
Direction of cable terminal
|
variable
|
busbar thickness
|
5; 10 mm
|
Poles
|
3
|
Fuse monitoring
|
Electronic Fuse Monitoring Unit ES10 Rated operational voltage: AC400-500V (+/-10%) Power supply: Self-powered Input power: 1,5VA Overvoltage category:
- 230/400V: III (4kV)
- 500V: II (4kV)
Input resistance: >1k Ohm/V Temperature range: -5 up to + 55
Relay output: 1NC/1NO Switching power:
- AC250V: 1A
- DC220V: 0,3A
- DC30V: 2A
Operation indicator: 1 LED green Alarm indicator: 3 LED (F1, F2, F3) red Functional test: Test key for relay + LEDs EMV: IEC 61000-4-5/IEC 61000-4-4
|
|
|
|
Descriptionaccording to EN60947-3, size NH3 - 630A, 3pole
for mounting on 3pole busbar system with 60mm centre-to-centre distance
with box clamp R300, max. clamping range: 95-300mm² Al/Cu
cable terminal at top or bottom side, at customers option
with electronic fuse-monitoring unit ES10
Type:
|
KETO-3-3/60/AOU/R300/ES10
|
Size:
|
NH3
|
Rated operating voltage Ue:
|
500 V
|
Rated operating current Ie:
|
630 A
|
Cable terminal:
|
Frame clamp R300 95-300mm²
|
Direction of cable terminal:
|
variable
|
busbar thickness:
|
5; 10 mm
|
Poles:
|
3
|
Fuse monitoring:
|
Electronic Fuse Monitoring Unit ES10 Rated operational voltage: AC400-500V (+/-10%) Power supply: Self-powered Input power: 1,5VA Overvoltage category:
- 230/400V: III (4kV)
- 500V: II (4kV)
Input resistance: >1k Ohm/V Temperature range: -5 up to + 55
Relay output: 1NC/1NO Switching power:
- AC250V: 1A
- DC220V: 0,3A
- DC30V: 2A
Operation indicator: 1 LED green Alarm indicator: 3 LED (F1, F2, F3) red Functional test: Test key for relay + LEDs EMV: IEC 61000-4-5/IEC 61000-4-4
|
|
Descriptionaccording to EN60947-3, size NH3 - 630A, 3pole
for mounting on 3pole busbar system with 60mm centre-to-centre distance
with box clamp R300, max. clamping range: 95-300mm² Al/Cu
cable terminal at top or bottom side, at customers option
with electronic fuse-monitoring unit ES10
|
Type
|
KETO-3-3/60/AOU/R300/ES10
|
Size
|
NH3
|
Rated operating voltage Ue
|
500 V
|
Rated operating current Ie
|
630 A
|
Cable terminal
|
Frame clamp R300 95-300mm²
|
Direction of cable terminal
|
variable
|
busbar thickness
|
5; 10 mm
|
Poles
|
3
|
Fuse monitoring
|
Electronic Fuse Monitoring Unit ES10 Rated operational voltage: AC400-500V (+/-10%) Power supply: Self-powered Input power: 1,5VA Overvoltage category:
- 230/400V: III (4kV)
- 500V: II (4kV)
Input resistance: >1k Ohm/V Temperature range: -5 up to + 55
Relay output: 1NC/1NO Switching power:
- AC250V: 1A
- DC220V: 0,3A
- DC30V: 2A
Operation indicator: 1 LED green Alarm indicator: 3 LED (F1, F2, F3) red Functional test: Test key for relay + LEDs EMV: IEC 61000-4-5/IEC 61000-4-4
|
|
|